I. Main Physical Requirements

 

1. Tap Density (Tap Density Tester)
2. Compacted Density (Powder Compactor)
3. Particle Size (Particle Size Analyzer)
4. Specific Surface Area (Specific Surface Area Analyzer)
5. Particle Shape (SEM)
6. XRD (X-ray Diffractometer)

 

lithium iron phosphate

 

II. Main Chemical Composition Requirements

 

1. Moisture Content/ppm (Moisture Tester)
2. Carbon Content (Carbon-Sulfur Analyzer)
3. pH (pH Meter)
4. Ni+Cr+Cu+Zn/ppm (ICP)
5. Na+K/ppm (ICP)
6. Li% (ICP)
7. Fe% (Potassium Dichromate Method)
8. P% (Precipitation Method)
9. ​​Magnetic Substance/ppm (ICP)

 

III. Electrochemical Performance Requirements

 

1. 0.1C First Charge Specific Capacity (mAh/g)
2. 0.1C First Discharge Specific Capacity (mAh/g)
3. The initial coulombic efficiency electrochemical performance requires preparation of a half-cell (Li as the negative electrode) and charge-discharge testing at 25°C ± 2°C, 2.0-3.75V.

 

The testing parameters are generally the same for related cathode materials, not just lithium iron phosphate. These include lithium cobalt oxide, lithium manganese oxide, NCM, and lithium manganese iron phosphate. There are some differences in the element type and voltage range of the button cell.

 