1-32 Series 200A Charge 300A Discharge BMS Testing Equipment
Product Description
ACEY-BP32-200A300A battery management system tester is designed to test and validate the performance of Battery Management Systems (BMS). This device automatically tests the various functions of BMS by simulating real battery operating conditions, ensuring its reliability, safety, and stability.
Main functions
With test function of overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.
Features
- 1-32 series battery management system tester, high degree of automation, fast testing speed and high testing accuracy.
- It can test the BMS of MCN battery, LiFeO4 battery and cobalt acid battery.
- This machine is required to be connected to a computer, the system generally requires an XP system, the interface of tester and computer is RS232.
Technical Parameter
(1)Input power supply: 180~240V 50/60HZ
(2)Power standard supply: AC 220V/50HZ,Range:±10%
(3)The voltage of charge and discharge: 5000mV ~102000mV
(4)It can test and set the voltage range when this machine is charging and discharging..
(5)Current accuracy: ±(0.1%FS+0.1%RD)
(6)Voltage accuracy: ±(0.1%FS+0.1%RD)
(7)Current resolution: 1mA (smallest unit)
(8)Voltage resolution: 1mV (smallest unit)
(9)Cycles: 1~9999
(10)With log function, including operation records and exception records during the whole process of testing, which can be used for traceability of the testing process.
(11)Data processing, human-machine interface
(12)Export data formation:Excel
(13)Interface:RS232
(14)Accuracy calibration/software calibration
(15)With scan code start function
(16)MES system connection
Specification
|
No. |
Function |
Range |
Accuracy |
unit |
|
1 |
Self-consumption of single cell |
0--500 |
±0.1 |
uA |
|
2 |
Self-consumption |
0--5000 |
±1 |
uA |
|
3 |
Overcharge voltage |
500--5000 |
±1 |
mV |
|
4 |
Overcharge recovery voltage |
500--5000 |
±1 |
mV |
|
5 |
Overcharge voltage protection delay |
0--10000 |
±1 |
mS |
|
6 |
Overdischarge voltage |
500--5000 |
±1 |
mV |
|
7 |
Overdischarge recovery voltage |
500--5000 |
±1 |
mV |
|
8 |
Overdischarge voltage protection delay |
0--10000 |
±1 |
mS |
|
9 |
Overcharge protection current protection value |
0.1--200 |
±0.01 |
A |
|
10 |
Overcharge protection current protection delay |
0--20000 |
±1 |
mS |
|
11 |
Overdischarge protection current protection value |
0.1--300 |
±0.01 |
A |
|
12 |
Overdischarge protection current protection delay |
0.1--20000 |
±1 |
mS |
|
13 |
Equalization function opening voltage |
500--5000 |
±1 |
mV |
|
14 |
Equalizing current |
1--500 |
±1 |
mA |
|
15 |
Charging current |
0.1--120 |
±0.01 |
A |
|
16 |
Discharging current |
0.1--120 |
±0.01 |
A |
|
17 |
Charging time |
0--100 |
±1 |
S |
|
18 |
Discharging time |
0--100 |
±1 |
S |
|
19 |
The difference of single cell self-consume |
0-500 |
±0.1 |
uA |
|
20 |
Resistance |
0-999 |
±1 |
mΏ |
|
21 |
Short circuit protection time |
0--5000 |
±1 |
uS |
|
22 |
The charging voltage of single cell |
500--5000 |
±1 |
mV |
|
23 |
The discharging voltage of single cell |
500--5000 |
±1 |
mV |
|
24 |
Open circuit voltage |
160000 |
±1 |
mV |
|
25 |
Number of voltage analogs |
32 |
0 |
PCS |
Product Details



Hot Tags: 32s 200a charge 300a discharge bms testing equipment, China 32s 200a charge 300a discharge bms testing equipment manufacturers, suppliers, sorting machine, prismatic battery pack assembly equipment, internal resistance tester, Battery Labeling Machine, bms testing machine, Electrode Stacking Machine