1-24S 50A Charge 120A Discharge BMS Testing Machine
Product Description
ACEY-BP24-50A120A BMS tester is specifically designed to test and validate the performance of Battery Management Systems (BMS). BMS is a key component of electric vehicles (EVs), energy storage systems, and various lithium battery packs, responsible for monitoring battery status, balancing battery charging and discharging, providing safety protection, etc.
The main function of BMS Tester is to simulate real battery operating conditions, conduct automated testing of various functions of BMS, and ensure its reliability, safety, and stability.
Function introduce
1)1-24 series battery management system tester, high degree of automation, fast testing speed and high testing accuracy. With test function of overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.
2)It can test the BMS of MCN battery, LiFeO4 battery and cobalt acid battery.
3)This machine is required to be connected to a computer, the system generally requires an XP system, the interface of tester and computer is RS232.
Specification
|
No. |
Function |
Range |
Accuracy |
unit |
|
1 |
Self-consumption of single cell |
0--500 |
±0.1 |
uA |
|
2 |
Self-consumption |
0--5000 |
±1 |
uA |
|
3 |
Overcharge voltage |
500--5000 |
±1 |
mV |
|
4 |
Overcharge recovery voltage |
500--5000 |
±1 |
mV |
|
5 |
Overcharge voltage protection delay |
0--10000 |
±1 |
mS |
|
6 |
Overdischarge voltage |
500--5000 |
±1 |
mV |
|
7 |
Overdischarge recovery voltage |
500--5000 |
±1 |
mV |
|
8 |
Overdischarge voltage protection delay |
0--10000 |
±1 |
mS |
|
9 |
Overcharge protection current protection value |
0.1--50 |
±0.01 |
A |
|
10 |
Overcharge protection current protection delay |
0--20000 |
±1 |
mS |
|
11 |
Overdischarge protection current protection value |
0.1--120 |
±0.01 |
A |
|
12 |
Overdischarge protection current protection delay |
0.1--20000 |
±1 |
mS |
|
13 |
Equalization function opening voltage |
500--5000 |
±1 |
mV |
|
14 |
Equalizing current |
1--500 |
±1 |
mA |
|
15 |
Charging current |
0.1--30 |
±0.01 |
A |
|
16 |
Discharging current |
0.1--120 |
±0.01 |
A |
|
17 |
Charging time |
0--30 |
±1 |
S |
|
18 |
Discharging time |
0--60 |
±1 |
S |
|
19 |
The difference of single cell self-consume |
0-500 |
±0.1 |
uA |
|
20 |
Resistance |
0-999 |
±1 |
mΏ |
|
21 |
Short circuit protection time |
0--5000 |
±1 |
uS |
|
22 |
The charging voltage of single cell |
500--5000 |
±1 |
mV |
|
23 |
The discharging voltage of single cell |
500--5000 |
±1 |
mV |
|
24 |
Open circuit voltage |
102000 |
±1 |
mV |
|
25 |
Number of voltage analogs |
24 |
0 |
PCS |
Product Details



Hot Tags: 24s 50a charge 120a discharge bms testing machine, China 24s 50a charge 120a discharge bms testing machine manufacturers, suppliers, Bms Tester Machine, bms tester