30V 40A Energy-Feedback Lithium Battery Pack Test System
Product Description
ACEY-BA3040-20 battery aging machine is used to test the lifespan, reliability, capacity and other parameters of the battery pack through cyclic charge and discharge test.
Function
- Each channel operates independently for charging/discharging and battery characteristic testing, programmable via software for current and voltage control within range.
- Includes reverse connection, abnormal voltage/current line detection, power-off, overcurrent, overvoltage, and overtemperature protection to ensure test safety.
- Supports user-defined steps, variable programming, and multi-level loop nesting for complex test sequences.
- Each channel has an independent programmable CC/CV source and can run test steps separately or in groups.
- After power failure or communication loss, the system automatically resumes the interrupted test step.
- Detects abnormal voltage/current fluctuations, triggers alarms, and pauses testing when limits are exceeded.
- Built-in log system records full test history and exceptions for traceability and analysis.
- Allows selection and comparison of multiple cycles and curve combinations for in-depth data visualization.
- Smooth current ramp-up prevents instantaneous surge and thermal shock to batteries or connectors.
- Seamless constant current to constant voltage switching with no impact or overshoot, protecting battery PCBs.
- No current spikes during step start or CC–CV transition; ensures stable test performance.
- Even if the protection board fails or disconnects, pulse voltage at the battery terminal remains below 10V.
Features
1.Equipment accuracy (0.1%RD +0.1%FS), high stability;
2.Independent charging and discharging conditions can be set after free grouping for each channel;
3.Complete input and output, software and hardware protection, reverse connection protection, power-off connection protection and other functions;
4.Channel start without impact current, constant current to constant voltage seamless transition, without any current surge;
5.Network integrated management, a computer centralized control, support remote monitoring;
6.Modular design concept, box plug-in design, easy to maintain;
7.Clear and comprehensive data, real-time monitoring and uploading MES system;
8.The cabinet can be extended.
Technical parameter
| No. | Project | Functional Requirements | ||
| 1 | Number of cabinet channels | 20 channels | ||
| 2 | Channel action mode | Completely independent | ||
| 3 | Main channel operating mode | Charging: constant current CC, constant current constant voltage charging CCCV; Discharge: constant current discharge CD, constant power CP; | ||
| Let it stand and stop. | ||||
| Main Channel Test Stop Conditions | Time, voltage, current, capacity, etc. | |||
| 4 | Main channel voltage | Charging voltage range | 10V ~ 30V | |
| Discharge voltage range | 10V ~ 30V | |||
| Accuracy | ±(0.1%RD+0.1%FS) | |||
| Resolution | 1mV | |||
| Main channel current | Maximum output current | Charge current 40A, discharge current 40A, | ||
| Minimum output current | 100mA | |||
| Accuracy | ±(0.1%RD+0.1%FS) | |||
| Resolution | 1mA | |||
| Power | Output power | Single channel continuous operation maximum power 1200W | ||
| Auxiliary channel parameter cutoff function | You can set the main channel step to stop or switch when the auxiliary channel signal reaches a certain condition. | |||
| 5 | Control Procedure | 1. Support data protection due to power failure, manual stop and connection from data files | ||
| Continued testing. | ||||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, | ||||
| Current upper limit, voltage and current trend. | ||||
| The auxiliary channel protection conditions can be set, and the parameters can be set include: upper voltage limit, lower voltage | ||||
| Limit, upper temperature limit, lower temperature limit. | ||||
| Number of cycles | Maximum 9999 | |||
| Step time unit | Support h, min, s format | |||
| Data upload interval | Minimum 5S | |||
| 6 | Data Display Mode | Cycle List | There are cycle number, charge/discharge capacity, charge/discharge efficiency, Charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | There are process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detail List | There are record serial numbers, system time, cumulative time, voltage, Current, energy, power, etc. | |||
| 7 | Data Export Method | The system supports data export to both Excel and dedicated chart files, enabling comprehensive analysis through various curves including charge-discharge efficiency, voltage/capacity over time characteristics, and current profiles. All graphical data can be further imported into Excel for customized processing and reporting. | ||
| line into EXCEL. | ||||
Product Details




Hot Tags: 30v 40a energy-feedback battery pack test system, China 30v 40a energy-feedback battery pack test system manufacturers, suppliers, Battery Charge Discharge Tester, aging machine