Lithium Battery Cycler Tester
video
Lithium Battery Cycler Tester

Lithium Battery Cycler Tester

Item Name:Lithium Battery Cycler Tester
Item No.:ACEY-HRCDS-60V100A
Order(Moq): 1 set
Compliance: CE Certified
Package: Plywood Case
Product Origin: China
Warranty: One-year warranty with lifetime support
Payment: T/T, Western Union, PayPal, Ali Trade Assurance

60V 100A Lithium Battery Pack Cycler Tester

 

Product Description

 

ACEY-HRCDS-60V100A battery pack testing machine mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.

 

Function

 

Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.

 

Features

 

  1. Power feedback to grid with direct current bus efficiency ≥85%: Both charging and discharging is energy-saving which saves a lot of electric power expenses and air-conditioner fees.
  2. CCCV charge: CC charge transfer to CV charge smoothly, without any impact, which can avoid the micro-shot circuit due to high temperature of peak current impact or to avoid PCB protection or second protection action caused by over-charging.
  3. Current and voltage sampling is of high stability and accuracy: this equipment applied 16bit bipolar ADC/DAC unit, to ensure voltage sampling high accuracy and long-term stability.
  4. User management includes authority management, role management and user management. Managers can set management permissions for each function module of the software, and set multiple user IDs according to the operator's permission requirements.
  5. DCIR: four DCIR test schemes are supported to meet different test requirements.
  6. Voltage clamp function: when battery does protect action through charging process, voltage clamp to pre-set voltage can protect battery or PCB from damage.
  7. The recording conditions can be set by sections in the test step, and the intelligent data management record can be implemented.
  8. Each channel has a built-in CAN and RS485 communication module to support BMS CAN communication function: collect the total voltage, total current, single cell voltage, temperature and other data of BMS system in real time, and make synchronous comparison with CDS voltage and current data. When setting BMS voltage, current, temperature and other data to a certain condition, the main channel steps will stop or convert, and the specific reading information will be provided by the customer.
  9. Support one click DBC import and manual customization of BMS protocol functions, and support sampling different BMS protocols for each channel.
  10. It supports user-defined signal sets. Users can customize the setting name according to their own needs and data recording requirements. By adding "sub semaphore" as protection parameters, multiple protection parameters can be set through the operators "maximum value, minimum value, difference value, mean value, +, -,×,÷, and, or, exponential variance, sine and cosine "function and other numerical relations are calculated, and the obtained results can generate new judgment conditions.

 

Technical parameter

 

No.

Item

HRCDS-60V100A

1

Main channels

1CH/ module

2

Output power

The maximum power of channel operation is 6kW; timeless

3

Output power stability

±0.1%FS

4

Power quality at input side

Power factor

>99%(full load)

Total harmonic distortion rate

≤5%(full load)

5

Energy consumption parameters

Standard sine wave feedback energy, high efficiency (optimal efficiency 85%%)

6

Main channel working mode

Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV

Discharge: CD, CP, CR

Still

Working condition test; Pulse test.

7

Main channel Voltage

Single channel test range

0.2V-60V, The intermediate value is continuously adjustable (wide test range, applicable to the test requirements of various battery modules)

Min. discharge voltage

12V

Accuracy

±0.05%FS

Resolution

1mV

Main channel Current

Single channel test range

±100A

Min. output current

150mA

Accuracy

±0.05%FS

Resolution

1mA

Current start response time

<5ms(10%~90%FS)

Time

Resolution

10ms

Auxiliary voltage (Optional)

Range

DC: 0-5V

Accuracy

±0.05%FS

Resolution

1mV

Auxiliary temperature (Optional)

Range

﹣20℃~100℃

Accuracy

±1℃(0℃~70℃)

Resolution

0.1℃

8

Communication

LAN

Battery BMS communication

Support CAN 2.0A, CAN 2.0B; RS485 communication

Support DBC import, realize data reading with BMS CAN, and participate in process control

9

Control program

Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.

Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, maximum temperature, minimum temperature, etc.

Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.

Cycle time

Max. 10000

Programmable step

Max. 10000

Nested loop

Max. 10 layers

Step time range

No limit, support h, min, s

Data record

Time≥10ms,Voltage≥0.1%FS, Current ≥0.1%FS

Program feature

Each step has one or multiple exit

10

Working mode (Unit voltage and temperature are optional)

Constant current charging

Battery voltage, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.

Constant voltage charging

Current, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.

Constant current and constant voltage charging

Battery voltage, current, time, capacity, energy, temperature, cell voltage, cell voltage difference, RSOC cut-off.

Shelve

Deadline

Constant current discharge

Battery voltage, time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.

Constant power discharge

Battery voltage, current, time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.

Constant resistance discharge

Battery voltage, current, hour time, capacity, energy, temperature, cell voltage, cell voltage difference cut-off.

11

Data display(Unit voltage and temperature are optional)

Cycle list

Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.

Process list

Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc.

Detail list

Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, monomer voltage l -- monomer voltage n, monomer voltage range etc.

12

Data export

Data can be exported as EXCEL, TXT or diagram. Provide data analysis curves and data lists in various ways, such as charge discharge curve, capacity decay rate, cycle life curve, charge discharge voltage, current, capacity, current time characteristics, etc

13

Data saving

Save as files

14

Curves type

X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity

Y-coordinate: total voltage, current, capacity, power, monomer voltage l-monomer voltage n, temperature 1-monomer temperature n, etc

15

Input protection

Overvoltage, overcurrent, phase loss, over temperature, protection alarm;

Output protection

Overvoltage, overcurrent, short circuit, capacity, temperature, single overvoltage and single undervoltage protection; No output when the battery voltage is not detected;

Power off protection

After external power failure, the battery and equipment are automatically disconnected, effectively avoiding accidents caused by re energization;

Hardware protection

Power off protection, open circuit protection and short circuit protection; Reverse connection of battery, wrong connection protection, overcurrent protection, overvoltage protection, overtemperature protection, hardware overvoltage, undervoltage and overcurrent protection;

Short circuit protection

External short circuit;

Software protection

Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection, equipment communication abnormal protection, auxiliary module communication abnormal protection;

Warning function

Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.

16

Barcode scan

Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system.

17

Cooling method

Forced Fan-cooled

18

Sampling terminals

Four-polar sampling. Copper nose or other fixture.

19

Auxiliary channel acquisition line

The length of acquisition cable can be adjusted according to the actual situation

20

Noise

Less than 70dB

IP grade

IP20

21

Repair

Modularized structure. Can be replaced or repair with spare parts.

Product Details

Battery Pack Test System
Lithium Battery Testing Equipment
Lithium Ion Battery Testing Machine
 

Hot Tags: lithium battery cycler tester, China lithium battery cycler tester manufacturers, suppliers, aging machine, Battery Charge Discharge Tester