6V 125A 8CHS Regenerative Battery Charge Discharge Tester for Li-Ion/Lead-acid/Ni-Cd/NiMH Battery
Product Description
ACEY-HRCDS-6V125A-8CH energy-feedback lithium ion cell tester is used for cycle life tests and quality control in the production or experimentation of various battery types, including lithium-ion, lead-acid, nickel-cadmium, and nickel-metal hydride batteries.
It conducts comprehensive tests such as battery cycle life, capacity, charging and discharging characteristics, charge retention capacity, charging and discharging efficiency, as well as tolerance tests for overcharging and over-discharging rates.
Working Environment
- Power supply of the whole cabinet: AC 380V±10%, frequency: 50HZ±5%.
- Maximum input power of the whole cabinet: 8 KW (8CH)
- Working temperature: 0℃-45℃.
- Ambient humidity: not more than 85% R.H (no water vapor condensation).
- Environment without strong vibration, no corrosive gas and flammable and explosive gas.
Product Features
- Current support multi-range: 0.02A-25A (accuracy ≤ 0.03%FS), 25A-60A (accuracy ≤ 0.03%FS), 60A-125A (accuracy ≤ 0.03%FS).
- Minimum discharge voltage**: -6V.
- High reliability, low noise, and high energy density**, making it flexible for laboratory use.
- Energy feedback (optimal grid efficiency of 70%)**: Energy feedback type, both charging and discharging are energy-efficient, saving significant electricity costs and reducing air conditioning expenses caused by heat dissipation.
- Fixture contact impedance monitoring**: Prevents safety issues caused by poor terminal contact or oxidation over time.
- CCCV charging**: Seamless transition during the charging process without any voltage or current surges, effectively preventing heat concentration due to peak currents, which could lead to electrode powder shedding, micro-shorts, islanding effects, or overcharging, triggering PCB protection mechanisms.
- Stable and high-precision current and voltage sampling**: Utilizes high-precision, high dynamic range ADC/DAC units, ensuring high voltage sampling accuracy and long-term stability.
- DL dynamic load protection function**: Effectively protects batteries during charging and discharging, preventing sparks and avoiding current surges caused by loose connectors, thereby safeguarding battery components such as MOSFETs and fuses.
- Voltage clamping function**: During charging, clamps the voltage to a safe level in case of battery protection activation or equipment abnormalities, preventing damage to the battery or battery protection board.
- ECD & EVD protection**: Avoids and identifies batteries that activate protection under unqualified conditions, stopping charging or discharging prematurely.
- Rich software features**: Includes "working condition simulation testing" and "charge-discharge testing," paired with a professional data analysis software platform, enabling rapid data analysis during R&D testing. Working condition simulation testing supports the import of condition files (Excel format, time-current, or time-power modes) for millisecond-level test verification.
- Third-party device control support**: Controls devices such as environmental chambers during testing, with related test data saved together to meet battery testing requirements (optional, third-party protocols required).
- Capacity calibration function**: Designates a specific step's discharge capacity as a benchmark for current and capacity judgment conditions in various cycle tests.
- RSOC capacity recharge testing support**: Uses the charge/discharge capacity from the previous cycle (or cumulative capacity from earlier steps) as a benchmark for setting capacity judgment conditions in the next step.
- Cumulative capacity SOC function (AH calculator)**: Calculates real-time cumulative capacity based on preset cell capacity, serving as a step judgment condition.
- Single-channel automatic Excel export**: Defines relevant time nodes/export paths to automatically generate Excel files for the corresponding channel.
- Data statistics function**: Includes online and historical data statistics.
technical parameters
| No. | Item | ACEY-HRCDS-6V125A-8CH | ||
| 1 | Main channels | 8CH/ module | ||
| 2 | Channel working mode | Completely independent. | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. | ||
| Discharge: CD, CP, CR, DCCV. | ||||
| Still, Pulse test, Working Condition test, DCIR test. | ||||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | -6V~6V | |
| Min. discharge voltage | 0V (device port voltage) | |||
| Accuracy | ≤0.05%FS(@25℃±10℃),≤0.1%FS(@0-15℃,35-45℃) | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±125A | ||
| Min. output current | 20mA | |||
| Accuracy |
20mA--25A:0.03%FS(@25℃±10℃) |
|||
|
25A--60A:0.03%FS(@25℃±10℃) |
||||
|
60A--125A:0.03%FS(@25℃±10℃) |
||||
| Resolution | 1mA | |||
| Current start response time | <5ms(10%FS~90%FS) | |||
| Time | Resolution | 10mS | ||
| Auxiliary temperature (Optional) | Range | -20℃~100℃ | ||
| Accuracy | ±1℃(0℃~70℃) | |||
| Resolution | 0.1℃ | |||
| Power | Output power | Single channel continuous working power 750W | ||
| Stability | ±0.1%FS | |||
| 5 | Communication | LAN | ||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9999 | |||
| Programmable step | Max. 9999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Maximum recording time: 10ms, voltage ≤0.03%FS, current ≤0.03%FS | |||
| Program feature | Each step has one or multiple exit | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection. | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
| 13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
| 14 | Energy consumption | Discharge power feedback to grid | ||
| 15 | Cooling method | Forced Fan-cooled | ||
| Noise | Less than 70dB | |||
| IP grade | IP20 | |||
| 16 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
| 17 | Software update | Provide regular software upgrade services until the hardware is incompatible. | ||
Product Details






Hot Tags: 6v 125a regenerative battery charge discharge tester, China 6v 125a regenerative battery charge discharge tester manufacturers, suppliers, battery cell tester for industrial applications, battery cell tester for operational management applications, battery cell voltage testing system, battery cell tester for incoming inspection, battery cell lifespan test service, battery cell analyzer tool