1-32S 200A Charge 300A Discharge Bms Testing Equipment
Product Description
The BMS tester features a high level of automation, rapid testing capabilities, and exceptional accuracy. It is designed to evaluate the functionality of Battery Management Systems (BMS) for MCN batteries, LiFePO4 batteries, and lithium cobalt oxide batteries. The system provides real-time monitoring of key parameters such as battery voltage, temperature, operating current, and remaining charge. Based on these metrics, it assesses the battery's condition and initiates appropriate actions to prevent issues like overcharging or overdischarging, ensuring optimal battery performance and safety.
Technical parameter
- Input power supply: 180~240V 50/60HZ,Power: 700W
- Power standard supply: AC 220V/50HZ,Range:±10%
- The voltage of charge and discharge:5000mV ~102000mV
- It can test and set the voltage range when this machine is charging and discharging..
- Current accuracy::±(0.1%FS+0.1%RD)
- Voltage accuracy±(0.1%FS+0.1%RD)
- Current resolution:1mA (smallest unit)
- Voltage resolution:1mV (smallest unit)
- Cycles:1~9999
- With log function, including operation records and exception records during the whole process of testing, which can be used for traceability of the testing process.
- Data processing, human-machine interface
- Export data formation:Excel
- Interface:RS232
- Accuracy calibration/software calibration
- With scan code start function
- MES system connection
Tester Function
|
No. |
Function |
Range |
Accuracy |
unit |
|
1 |
Self-consumption of single cell |
0--500 |
±0.1 |
uA |
|
2 |
Self-consumption |
0--5000 |
±1 |
uA |
|
3 |
Overcharge voltage |
500--5000 |
±1 |
mV |
|
4 |
Overcharge recovery voltage |
500--5000 |
±1 |
mV |
|
5 |
Overcharge voltage protection delay |
0--10000 |
±1 |
mS |
|
6 |
Overdischarge voltage |
500--5000 |
±1 |
mV |
|
7 |
Overdischarge recovery voltage |
500--5000 |
±1 |
mV |
|
8 |
Overdischarge voltage protection delay |
0--10000 |
±1 |
mS |
|
9 |
Overcharge protection current protection value |
0.1--200 |
±0.01 |
A |
|
10 |
Overcharge protection current protection delay |
0--20000 |
±1 |
mS |
|
11 |
Overdischarge protection current protection value |
0.1--300 |
±0.01 |
A |
|
12 |
Overdischarge protection current protection delay |
0.1--20000 |
±1 |
mS |
|
13 |
Equalization function opening voltage |
500--5000 |
±1 |
mV |
|
14 |
Equalizing current |
1--500 |
±1 |
mA |
|
15 |
Charging current |
0.1--120 |
±0.01 |
A |
|
16 |
Discharging current |
0.1--120 |
±0.01 |
A |
|
17 |
Charging time |
0--100 |
±1 |
S |
|
18 |
Discharging time |
0--100 |
±1 |
S |
|
19 |
The difference of single cell self-consume |
0-500 |
±0.1 |
uA |
|
20 |
Resistance |
0-999 |
±1 |
mΏ |
|
21 |
Short circuit protection time |
0--5000 |
±1 |
uS |
|
22 |
The charging voltage of single cell |
500--5000 |
±1 |
mV |
|
23 |
The discharging voltage of single cell |
500--5000 |
±1 |
mV |
|
24 |
Open circuit voltage |
160000 |
±1 |
mV |
|
25 |
Number of voltage analogs |
32 |
0 |
PCS |
Product Details







Hot Tags: 1-32 series bms tester machine, China 1-32 series bms tester machine manufacturers, suppliers, Battery Management System Test Equipment, bms testing machine