100V 30A charge 200A discharge Battery Comprehensive Testing System
Product Description
This equipment is designed to measure a range of battery parameters, including open-circuit voltage, AC internal resistance, continuous charge and discharge currents and voltages, overcurrent protection thresholds for both charging and discharging, short-circuit protection response time, overcurrent delay duration, and post-test voltage levels.
The device initiates testing either through infrared barcode scanning for serial number (SN) input or by automatically detecting voltage to start the process seamlessly.
Testing items
- Voltage: No-load voltage and Short circuit protection voltage after the test is completed,Range:0-100V
- Internal Resistance:ACIR1000hz, Range:0-4000mΩ
- Charging overcurrent protection current , Range:0-30A.
- Continuous charging current, Range:0-30A.
- Continuous charging voltage monitoring, Range:0-100V.
- 6-1Discharge overcurrent protection current and delay tim, Rang of current:0-200A,Overcurrent maximum power :20KW. 6-2Overcurrent test mode: (1) Step test (2) quick test.
- Continuous discharge current, Range:0-200A.
- Continuous discharge voltage judgment, Range:0-100V.
- Short circuit protection time:≤1000μ, Max Short circuit current about 5000A
- Single cell voltage monitoring
- Appreciation of charge and discharge voltage:
- During the working test, if the power supply is cut off and the MOS tube of the protection board is turned off, no inrush current will be generated, and the protection board of the lithium battery pack will not be damaged.
- Supprot MES system
- Database: The software comes with a database, which can generate excel tables.
- Step-by-step mode: the test sequence can be adjusted automatically.
- Support chassis expansion.
Tech Parameter
- Voltage range: 0-100V resolution:1mV Accuracy 0.1%RD+0.1FS
- Internal resistance: 0-2000mΩ resolution:0.001mΩ Accuracy 0.1%RD+0.1FS
- Charge current: 0-30A resolution: 0.001A Accuracy 0.1%RD+0.1FS
- Discharge current: 0-200A , at the highest voltage, continued discharge current 200A,resolution:0.001A Accuracy 0.1%RD+0.1FS
- Overcurrent delay time: 0-30S resolution:1mS Accuracy 0.1%RD+0.1FS
- short circuit time: 0-2000μS resolution:1μS Accuracy 0.1%RD+0.1FS
- NTC range: 0-100K 0.001K
- R1 range: 0-100K 0.001K
- Power supply: AC 200V-240V
- Maximum working power for charging: 5000W(When charging with maximum current)
- Maximum working power for discharging: 20KW(When discharging with maximum current)
- surge voltage<15V
Product Details



Hot Tags: battery comprehensive testing system, China battery comprehensive testing system manufacturers, suppliers, Battery Comprehensive Tester, integrated tester